October 2024: Fractal Audio's VP4 Virtual Pedalboard has been added to the wiki.
Difference between revisions of "Global blocks"
Jump to navigation
Jump to search
Line 10: | Line 10: | ||
* AX8: ... | * AX8: ... | ||
− | = | + | =Wicked Wiki: global blocks= |
* [http://forum.fractalaudio.com/axe-fx-ii-discussion/49554-wicked-wiki-14-global-blocks.html?highlight=wicked+wiki Wicked Wiki thread.] | * [http://forum.fractalaudio.com/axe-fx-ii-discussion/49554-wicked-wiki-14-global-blocks.html?highlight=wicked+wiki Wicked Wiki thread.] | ||
− | = | + | =Exporting or backing up global blocks= |
* When backing up a preset with global blocks, you also always need to backup the System data too, to be able to restore the stored data. | * When backing up a preset with global blocks, you also always need to backup the System data too, to be able to restore the stored data. | ||
− | =Global blocks | + | =Global blocks and modifier parameters and controller settings= |
* Modifier settings are not saved within global blocks. The same goes for controllers settings. You can use [[Axe-Fx II: Recall Effect|Recall Effect]] in the Axe=-Fx II to copy controller settings from one preset to another, or use the editor. | * Modifier settings are not saved within global blocks. The same goes for controllers settings. You can use [[Axe-Fx II: Recall Effect|Recall Effect]] in the Axe=-Fx II to copy controller settings from one preset to another, or use the editor. | ||
− | =Global | + | =Global control of Bypass state= |
* The state (On/Off) of a Global block is saved per preset. This means you can set Global Block #1 Off in one preset, and On in another. | * The state (On/Off) of a Global block is saved per preset. This means you can set Global Block #1 Off in one preset, and On in another. | ||
* If you want global control of the bypass state of an effect block, here's a solution: | * If you want global control of the bypass state of an effect block, here's a solution: | ||
Line 26: | Line 26: | ||
*# This works with global and non-global blocks, and across all presets with the same effect block. | *# This works with global and non-global blocks, and across all presets with the same effect block. | ||
− | = | + | =Preset noise gate and preset input level as global blocks= |
* The Noise Gate in the GTE/IN menu, including the Level control on that page, can be linked to a global block. | * The Noise Gate in the GTE/IN menu, including the Level control on that page, can be linked to a global block. | ||
− | = | + | =Unlinking global blocks= |
* You can unlink a global block in the following ways: | * You can unlink a global block in the following ways: | ||
** Within the global block menu. | ** Within the global block menu. |
Revision as of 10:10, 9 October 2015
Contents
- 1 Global blocks: in the owner's manuals
- 2 Global blocks: supported by which Fractal Audio products?
- 3 Wicked Wiki: global blocks
- 4 Exporting or backing up global blocks
- 5 Global blocks and modifier parameters and controller settings
- 6 Global control of Bypass state
- 7 Preset noise gate and preset input level as global blocks
- 8 Unlinking global blocks
Global blocks: in the owner's manuals
- Axe-Fx II: 6 Global Blocks
- Axe-Fx II: 13 Backing Up and Restoring
Global blocks: supported by which Fractal Audio products?
- Axe-Fx II: yes.
- FX8: no.
- AX8: ...
Wicked Wiki: global blocks
Exporting or backing up global blocks
- When backing up a preset with global blocks, you also always need to backup the System data too, to be able to restore the stored data.
Global blocks and modifier parameters and controller settings
- Modifier settings are not saved within global blocks. The same goes for controllers settings. You can use Recall Effect in the Axe=-Fx II to copy controller settings from one preset to another, or use the editor.
Global control of Bypass state
- The state (On/Off) of a Global block is saved per preset. This means you can set Global Block #1 Off in one preset, and On in another.
- If you want global control of the bypass state of an effect block, here's a solution:
- Attach the Bypass parameter of the effect block to an External controller.
- In the I/O menu, switch the External controller between 0% or 100% to change the effect's Bypass state. Or assign a switch on your foot controller to the MIDI CC of the External Controller to switch the block.
- This works with global and non-global blocks, and across all presets with the same effect block.
Preset noise gate and preset input level as global blocks
- The Noise Gate in the GTE/IN menu, including the Level control on that page, can be linked to a global block.
Unlinking global blocks
- You can unlink a global block in the following ways:
- Within the global block menu.
- By using STRIP ALL GLOBAL DATA in Utility.
- By pressing Enter while in the Recall menu on the Axe-Fx II.