Always consult the official Owners Manuals first!
March 2024: all pages have been checked and are up-to-date

Difference between revisions of "FASLINK"

From Fractal Audio Wiki
Jump to navigation Jump to search
m (edited for readability)
 
(70 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[image:XLR.jpg|125px]]
 
 
__TOC__
 
__TOC__
=What is FASLINK=
+
=FASLINK=
  
FASLINK is a proprietary Fractal Audio communications link between the Axe-Fx II and the MFC-101 (FASLINK version 1), between the Axe-Fx III and FC controllers (FASLINK II), and between the FM3 and an FC controller (FASLINK II). FASLINK provides two-way communication and power via an XLR cable. XLR cables (microphone cables) are common, flexible and robust, supporting runs of hundreds of feet.
+
FASLINK is a proprietary Fractal Audio communications protocol. Between:
 +
* [[Axe-Fx II]] and [[MFC-101 MIDI foot controller]] it is known as '''FASLINK'''.
 +
* [[Axe-Fx III, FM9 and FM3]] and [[FC-6 and FC-12 foot controllers|FC controllers]] it is technically known as '''FASLINK II'''.
  
FASLINK replaces previous connection methods (MIDI and Ethernet).
+
FASLINK provides two-way communication and power via an XLR microphone cable. Such XLR cables are common, flexible and robust, supporting runs of hundreds of feet.
  
There are two versions of FASLINK:
+
It has replaced previous connection methods for Fractal Audio foot controllers using MIDI and Ethernet.
  
* '''FASLINK (original)''' – connects the Axe-Fx II and MFC-101
+
There's no need to power down the modeler when connecting the FC controller, <q>hot connecting</q> is supported.
* '''FASLINK II''' – connects the Axe-Fx III and FC foot controller(s), and the FM3 and FC foot controllers. It features a new protocol. Length limit is 100 feet ([http://forum.fractalaudio.com/threads/faslink-2-cable-length-limit.145778/#post-1723699 source])
 
  
[[image:Iii-rear-transparent.png|400px]] [[image:FM3-rear.png|300px]]
+
The maximum combined length of multiple cables is [http://forum.fractalaudio.com/threads/faslink-2-cable-length-limit.145778/#post-1723699 100 feet].
  
<blockquote>"FASLINK is not a balanced protocol. But it is robust because it uses high signaling levels. You can use any wire for FASLINK but ideally it should be shielded and a heavy enough gauge to carry up to 1A without significant voltage drop. If "I" were adapting FASLINK to CAT5 I would use each pair as a conductor. I.e. blue and blue/white tied together as one conductor, green and green/white tied together as another conducter. Then the drain wire (and maybe another conductor pair to ensure low resistance) connected to the XLR shield. FASLINK uses two conductors plus shield (standard mic cable). One conductor is power. The other conductor is data. The shield is the common return for the two conductors. We've tested FASLINK over 100m of cable. As long as the conductors are heavy enough so the voltage doesn't drop too much you can run it very long distances." [http://forum.fractalaudio.com/threads/faslink-2-wiring.144095/#post-1755571 source]</blockquote>
+
<blockquote>
 +
'''FRACTAL AUDIO QUOTES'''
 +
<HR>
 +
<blockquote>
 +
[http://forum.fractalaudio.com/threads/faslink-2-wiring.144095/#post-1755571]
 +
[…]
 +
FASLINK is not a balanced protocol. But it is robust because it uses high signaling levels. You can use any wire for FASLINK but ideally it should be shielded and a heavy enough gauge to carry up to 1A without significant voltage drop.
  
<blockquote>"The FASLINK port is protected against shorts." [http://forum.fractalaudio.com/threads/xl-lockup-when-faulty-faslink-xlr-is-connected.105500/#post-1262170 source]</blockquote>
+
If "I" were adapting FASLINK to CAT5 I would use each pair as a conductor. I.e. blue and blue/white tied together as one conductor, green and green/white tied together as another conducter. Then the drain wire (and maybe another conductor pair to ensure low resistance) connected to the XLR shield.
  
=Available on which products=
+
FASLINK uses two conductors plus shield (standard mic cable). One conductor is power. The other conductor is data. The shield is the common return for the two conductors.
  
'''Axe-Fx III''' – Built-in FASLINK II support
+
We've tested FASLINK over 100m of cable. As long as the conductors are heavy enough so the voltage doesn't drop too much you can run it very long distances.
 +
</blockquote>
  
'''FM3''' – Built-in FASLINK II support
+
<blockquote>
 +
[https://forum.fractalaudio.com/threads/so-whats-new-on-the-iii-axe-fx-ii-vs-iii.134729/page-7#post-1592499]
 +
We rewrote everything using a client-server approach. You can have any number of clients attached, even multiple editors, and they all update automatically when something changes (even if changed from the front panel). The foot controllers are essentially clients as well.
 +
</blockquote>
  
'''Axe-Fx II XL and XL+''' – Built-in FASLINK support
+
<blockquote>
 +
[https://forum.fractalaudio.com/threads/small-bug-more-an-oversight-regarding-the-tuner.157332/post-1875003]
 +
The FC's are clients. They request data, they do not get data pushed.
 +
</blockquote>
  
'''Axe-Fx II Mark I and II''' – FASLINK adapter needed to convert wiring from Ethernet/Ethercon to XLR
+
<blockquote>
 +
[http://forum.fractalaudio.com/threads/presenting-the-axe-fx-iii.134717/page-21#post-1593269]
 +
[…]
 +
the communication protocol between the III and the FC's is proprietary and not MIDI-based. The FC's are sort of "dumb terminals". All the they do is tell the III "button #3 was pressed" and the III responds by saying "light LED ring #3 blue" or "display 'My Preset' on the main LCD". This way all the configuration data is on the III and when you backup you backup the foot controller as well. It also means if a foot controller fails you don't have to reprogram a new one (which is a big deal for touring acts where the gear gets hammered on and last second change-outs are common).
 +
</blockquote>
  
'''MFC-101 Mark III''' – Built-in FASLINK support
+
<blockquote>
 +
[http://www.thegearpage.net/board/index.php?threads/just-got-my-axe-iii-invite-anyone-try-integrating-it-with-a-helix-as-foot-controller-yet.1952049/page-4#post-26744244]
 +
[…]
 +
it's not standard MIDI. The Axe-Fx III uses a proprietary communication protocol. Devices can communicate over any physical layer by wrapping and unwrapping the comm protocol. Theoretically you can control it over MIDI, Ethernet, WiFi, RS-232, AppleTalk, Sneakernet, etc. The MIDI basics are there, of course, but to access the tuner, etc. you need to wrap and unwrap the protocol layer.
 +
</blockquote>
  
'''MFC-101 Mark I and II''' – FASLINK adapter needed to convert wiring from Ethernet/Ethercon to XLR
+
<blockquote>
 +
[https://forum.fractalaudio.com/threads/has-anyone-sniffed-looked-at-the-faslink-ii-protocol.176309/post-2141271]
 +
FASLINK is not MIDI. The FC-6/12 are "terminals". They record button presses and send the button press to the host. The host sends messages to the terminal which tells the terminal what color to display on the LEDs and what text to display on the LCDs.
 +
</blockquote>
  
'''FC controllers''' – Built-in FASLINK II support
+
<blockquote>
 +
[http://forum.fractalaudio.com/threads/xl-lockup-when-faulty-faslink-xlr-is-connected.105500/#post-1262170]
 +
The FASLINK port is protected against shorts.
 +
</blockquote>
 +
</blockquote>
  
=Setting up a FASLINK connection=
+
=Power and daisy-chaining=
  
'''Axe-Fx III''' – Connect the XLR cable between the Axe-Fx III and FC controller
+
You can daisy-chain up to four FC controllers using the FASLINK II <q>THRU</q> ports.
  
'''FM3''' – Connect the XLR cable between the FM3 and FC controller
+
Only the first FC controller gets its power from the Axe-Fx III, FM9 or FM3 through FASLINK II. Additional FC controllers have to be powered separately through their power ports. Use a 9-12V power supply, 1000 ma, negative center, 2.5mm barrel.
  
'''Axe-Fx II''' – Connect the XLR cable. Turn on FASLINK in the I/O menu
+
Two or more daisy-chained FC units can be forced to remain in sync, showing the same layouts, the same switches and switch states, AKA as <q>mirroring</q>.
  
'''MFC-101''' – Connect the XLR cable. Select the correct port in the MFC settings. WARNING: do NOT connect a power supply to the MFC-101 when using FASLINK
+
<blockquote>
 +
'''FRACTAL AUDIO QUOTES'''
 +
<HR>
  
=Providing power through FASLINK=
+
<blockquote>
 +
FASLINK powers the first FC. FC setup is same as Axe-Fx III.
 +
</blockquote>
  
A FASLINK II connection provides power (from the Axe-Fx III or FM3) to the first connected FC controller.
+
<blockquote>
 +
[https://forum.fractalaudio.com/threads/fas-link-cable-run-works-for-fc-6-but-not-fc-12.154527/post-1838351]
 +
The FC-12 uses more power because it has more LCDs. If the cable resistance is too high then there will be excessive voltage drop which could cause booting issues and other problems.
  
=Adapters for older hardware=
+
Using a cable snake is not recommended because the conductor gauge is small and the resistance will be high. We recommend a good quality dedicated XLR cable. Dim LEDs are an indication that there is excessive voltage drop on the cable.
 +
</blockquote>
  
The FASLINK XA-1 and XA-2 adapters convert the wiring on older Axe-Fx II and MFC-101 hardware (see above) from Ethernet/Ethercon to XLR. These adapters are "active" ([http://forum.fractalaudio.com/axe-fx-ii-discussion/95125-xa-1-faslink-adapter.html#post1139249 source]). They can be bought directly from [http://shop.fractalaudio.com Fractal Audio's online shop] and [http://g66.eu G66].
+
<blockquote>
 +
[https://forum.fractalaudio.com/threads/fas-link-cable-run-works-for-fc-6-but-not-fc-12.154527/post-1838845]
 +
The FC rated voltage is 9-12V but should work down to about 7V. If the snake is 100 ft. of 24 gauge wire then that would put you right at 7V. The FC-12 draws about 1A so Vdrop = 0.025 ohms/ft * 100 ft * 2 conductors * 1A = 5V drop. This is assuming the shield drain has the same resistance as the conductors.
  
The adapters do not support FASLINK II.
+
So, yeah, 100 ft snake is too long for an FC-12.
 +
</blockquote>
  
[http://www.fractalaudio.com/downloads/manuals/faslink/FASLINK-Adapters-Setup-Guide.pdf More information in the FASLINK Setup Guide]
+
<blockquote>
 +
[https://forum.fractalaudio.com/threads/fas-link-cable-run-works-for-fc-6-but-not-fc-12.154527/post-1838562]
 +
Dim LEDs are an indication that there is excessive voltage drop on the cable.
 +
</blockquote>
 +
 
 +
<blockquote>
 +
[http://forum.fractalaudio.com/threads/timing-on-availability-of-exact-specs-photos-of-fc-6-12.137939/page-4#post-1644453]
 +
They are phantom powered. You can daisy-chain up to four. Any daisy-chained units need their own power supply. IOW only the first unit in the chain is phantom powered.
 +
</blockquote>
 +
</blockquote>
 +
 
 +
=Issues? It's probably the cable=
 +
 
 +
If the FC controller won't power on properly, or if the processor shuts down or starts blinking all lights, it's almost certainly caused by the cable. Use another standard microphone cable instead.
 +
 
 +
=FASLINK adapters for legacy hardware=
 +
 
 +
The FASLINK XA-1 and XA-2 adapters convert the wiring on the Axe-Fx II Mark I and II, and the MFC-101 Mark I and II, from Ethernet/Ethercon to XLR. These adapters are <q>active</q>. The adapters do not support FASLINK II! Read the [[Owners_Manuals|FASLINK Setup Guide]] for more information.
 +
 
 +
Do NOT connect a power supply to the MFC-101 when using FASLINK.
  
 
[[file:FASLINK_adapters.png‎|150px|link=]]
 
[[file:FASLINK_adapters.png‎|150px|link=]]
Line 61: Line 118:
  
 
[[file:XA-2 diagram.png]]
 
[[file:XA-2 diagram.png]]
 +
  
 
[[category:Axe-Fx2]]
 
[[category:Axe-Fx2]]
 
[[category:Axe-Fx3]]
 
[[category:Axe-Fx3]]
 
[[category:FM3]]
 
[[category:FM3]]
 +
[[category:FM9]]
 
[[category:Remote]]
 
[[category:Remote]]
 +
[[category:All]]

Latest revision as of 21:47, 25 February 2024

FASLINK

FASLINK is a proprietary Fractal Audio communications protocol. Between:

FASLINK provides two-way communication and power via an XLR microphone cable. Such XLR cables are common, flexible and robust, supporting runs of hundreds of feet.

It has replaced previous connection methods for Fractal Audio foot controllers using MIDI and Ethernet.

There's no need to power down the modeler when connecting the FC controller, hot connecting is supported.

The maximum combined length of multiple cables is 100 feet.

FRACTAL AUDIO QUOTES


[1] […] FASLINK is not a balanced protocol. But it is robust because it uses high signaling levels. You can use any wire for FASLINK but ideally it should be shielded and a heavy enough gauge to carry up to 1A without significant voltage drop.

If "I" were adapting FASLINK to CAT5 I would use each pair as a conductor. I.e. blue and blue/white tied together as one conductor, green and green/white tied together as another conducter. Then the drain wire (and maybe another conductor pair to ensure low resistance) connected to the XLR shield.

FASLINK uses two conductors plus shield (standard mic cable). One conductor is power. The other conductor is data. The shield is the common return for the two conductors.

We've tested FASLINK over 100m of cable. As long as the conductors are heavy enough so the voltage doesn't drop too much you can run it very long distances.

[2] We rewrote everything using a client-server approach. You can have any number of clients attached, even multiple editors, and they all update automatically when something changes (even if changed from the front panel). The foot controllers are essentially clients as well.

[3] The FC's are clients. They request data, they do not get data pushed.

[4] […] the communication protocol between the III and the FC's is proprietary and not MIDI-based. The FC's are sort of "dumb terminals". All the they do is tell the III "button #3 was pressed" and the III responds by saying "light LED ring #3 blue" or "display 'My Preset' on the main LCD". This way all the configuration data is on the III and when you backup you backup the foot controller as well. It also means if a foot controller fails you don't have to reprogram a new one (which is a big deal for touring acts where the gear gets hammered on and last second change-outs are common).

[5] […] it's not standard MIDI. The Axe-Fx III uses a proprietary communication protocol. Devices can communicate over any physical layer by wrapping and unwrapping the comm protocol. Theoretically you can control it over MIDI, Ethernet, WiFi, RS-232, AppleTalk, Sneakernet, etc. The MIDI basics are there, of course, but to access the tuner, etc. you need to wrap and unwrap the protocol layer.

[6] FASLINK is not MIDI. The FC-6/12 are "terminals". They record button presses and send the button press to the host. The host sends messages to the terminal which tells the terminal what color to display on the LEDs and what text to display on the LCDs.

[7] The FASLINK port is protected against shorts.

Power and daisy-chaining

You can daisy-chain up to four FC controllers using the FASLINK II THRU ports.

Only the first FC controller gets its power from the Axe-Fx III, FM9 or FM3 through FASLINK II. Additional FC controllers have to be powered separately through their power ports. Use a 9-12V power supply, 1000 ma, negative center, 2.5mm barrel.

Two or more daisy-chained FC units can be forced to remain in sync, showing the same layouts, the same switches and switch states, AKA as mirroring.

FRACTAL AUDIO QUOTES


FASLINK powers the first FC. FC setup is same as Axe-Fx III.

[8] The FC-12 uses more power because it has more LCDs. If the cable resistance is too high then there will be excessive voltage drop which could cause booting issues and other problems.

Using a cable snake is not recommended because the conductor gauge is small and the resistance will be high. We recommend a good quality dedicated XLR cable. Dim LEDs are an indication that there is excessive voltage drop on the cable.

[9] The FC rated voltage is 9-12V but should work down to about 7V. If the snake is 100 ft. of 24 gauge wire then that would put you right at 7V. The FC-12 draws about 1A so Vdrop = 0.025 ohms/ft * 100 ft * 2 conductors * 1A = 5V drop. This is assuming the shield drain has the same resistance as the conductors.

So, yeah, 100 ft snake is too long for an FC-12.

[10] Dim LEDs are an indication that there is excessive voltage drop on the cable.

[11] They are phantom powered. You can daisy-chain up to four. Any daisy-chained units need their own power supply. IOW only the first unit in the chain is phantom powered.

Issues? It's probably the cable

If the FC controller won't power on properly, or if the processor shuts down or starts blinking all lights, it's almost certainly caused by the cable. Use another standard microphone cable instead.

FASLINK adapters for legacy hardware

The FASLINK XA-1 and XA-2 adapters convert the wiring on the Axe-Fx II Mark I and II, and the MFC-101 Mark I and II, from Ethernet/Ethercon to XLR. These adapters are active. The adapters do not support FASLINK II! Read the FASLINK Setup Guide for more information.

Do NOT connect a power supply to the MFC-101 when using FASLINK.

FASLINK adapters.png

XA-1 diagram.png

XA-2 diagram.png